All notable changes to the uniwire format and to the uniwire Python library are documented here. The format and the library are versioned separately: the format follows 1.y.z (see SPEC §9), the library follows its own semantic version. Before the library's 1.0, a 0.x.y release adds features and fixes that keep existing documents and code working, and a 0.x.0 release may break compatibility (described here, with what to change).

Unreleased

Changes to know

  • The format is a draft, version 1.0.0-draft (SPEC: "version 1.0 (draft)"): it may still change until it is adopted. Documents must declare "uniwire": "1.0.0-draft" or leave the field out; a document declaring another version (1.0.0, 1.1.0, 1.2.0...) is rejected with a message giving the value to write, so change the field to 1.0.0-draft. Libraries 0.1.8 and earlier reject documents declaring 1.0.0-draft: upgrade them.
  • Multi-line views draw the power diagram only, as the specification says (§7.1): the power tree (every node in it, whatever its type) and the power links (transfer, bypass, parallel, tie, infeed). They used to draw every controller, terminal block, sensor and meter placed through links, with their control, measure, data, trip and earth links, often shrinking a sheet to a third of its size. The new view option auxiliaries: true draws them as before.
  • No sheet is drawn below scale 0.6 any more (folio_split: auto): a min_scale below 0.6 is read as 0.6, and a way wider than a sheet (a long distribution below a device rather than a board) sends its branches to sheets of their own, with off-page references at both ends, before its busbar is cut, in both views. It was squeezed on one sheet at a third of its size (texts under 1 mm). folio_split: none still draws one sheet at whatever scale it needs.
  • The scale of a sheet is written in a "Scale" cell of the title block, next to the sheet number, instead of in the corner of the sheet (a sheet without a title block keeps it in its corner).
  • Sheet numbers of a drawing set: the views of a document are numbered one after the other, from the first_folio of the first view and of a later view that gives one, the total being total_folios (never less than the last sheet). A view drawn on its own (web editor, render tool, SVG export) now prints the numbers it has in the set, in its title blocks and in its "→ sheet n", "from -Q1 (sheet n)" and "continued on sheet n" references, as in the PDF of every view; it numbered its sheets from 1. The PDF bookmarks and references give the printed numbers too.
  • New info findings that many documents will now get: core.system-missing (no supply system declared: the conductors drawn are inferred from the devices), core.pen-split-missing (TN-C-S with no board saying where the PEN is split; the drawings split it at the first board) and core.symbol-text (generic loads and controllers without symbol_text, whose boxes stay empty or generic).
  • Multi-line drawings with no system declared (neither on the installation nor on the supply) take their conductors from what the devices and loads state: three phases only when one of them is on more than one phase or on L2 / L3, a neutral when one needs it, else one phase and the neutral. They were drawn with L1 L2 L3 N and four-pole devices whatever they held.
  • Multi-line drawings without a colour mode draw the protective conductor (PE) dash-dot, in black; it was a solid line like the phases. With the conductor colours it stays solid green/yellow.
  • Powers are per item: with count, a load's p_kW is that of one item (core.load-current, nfc15100.heating, the drawings). Six bundled examples gave the total and were corrected.

Format

  • Format 1.2: a document names the symbol set it is drawn with in symbols (iec by default, the built-in set). A set is registered in Python (uniwire.symbols.register_symbol_set) or by a package (entry point group uniwire.symbol_sets) and gives only the symbols it changes. A set that is not installed, a package that fails to load or a symbol that fails to draw gives the IEC symbol, with the warning core.symbol-set-unknown or core.symbol-set-error. uniwire symbols --set NAME draws every symbol of a set (example in examples/code/symbol_set.py). In multi-line views, switching and protective devices are drawn pole by pole and do not take the set's symbols. A 1.1 document is a valid 1.2 document, drawn as before.
  • Without a version change (the specification is still a draft), documents refused before are now read: the circuit schedule rows status, manufacturer, part_number, icu_kA, icw_kA and socket_type (titles in every language); dc on a breaker, as on switch_disconnector and spd (drawn as a DC line, L+ and L-); kind: "shunt" on an instrument_transformer, drawn as a resistor on the line, and in the multi-line view on the one conductor it measures (its phase, else L+ on a DC line, else L1); the cable marks keys U2, V2, W2; the view option auxiliaries.

Validation

  • More near-misses are read in canonical form, each reported by core.normalized: revision columns rev, by, note (as index, author, description), PLC module kinds written in full (digital_input, analog-outputs, MIXED_IO), a whole number for a quoted choice (EV charger mode: 3 as "3"), phases written as text ("3"), an unknown field given null (left out), and a view pitch_mm under 10 (read as 10).
  • A symbol_text longer than the six characters a symbol holds, which neither its spaces nor its initials bring down to six, keeps its first whole words ("Pump P-200" as "Pump", it was "Pump P"); a single word too long is cut with a full stop ("Ventilation" as "Venti.").
  • Messages say what to write: a value outside a list names that value and the allowed ones, a value under a minimum names both, an unknown field names a close field of the node ("did you mean 'ib_A'?") or the node types that have it, a text written where an object is expected says so, a duplicate id gives the path of each node, and residual-current fields written on a breaker (residual_mA, idn_mA, rcd_type...) point to an rcbo (or an rcd). A document still refused lists only the problems left once the near-misses are read.

Rule checks

  • New warnings: core.load-current, the current of a load more than 10% above the rating of the protection that feeds it alone (the message says when count is the cause); core.neutral-missing, a device with a neutral pole (1P+N, 3P+N) on a network without neutral (system 3P or 2P); core.folio-duplicate, two views starting at the same sheet number, the later one numbered after the sheets before it (before, two sheets had one number); core.folio-overlap, a view whose sheets would take numbers already given (a first_folio inside their range, or a view running into the next one's), renumbered silently before. The number of sheets is known only once the views are drawn, so core.folio-overlap is reported with the PDF of every view (page "About this document", uniwire render), not by check.
  • New info core.view-direction: a view whose direction is right or left is drawn top-down, which the reader is now told.
  • core.scope ("uniwire does not draw control schematics") also when the control devices are entered as controllers: a relay, a push button, a sensor or a lock on a control power supply, a reference after a folio number ("-21K4"), one controller per PLC or building controller input or output (function "DI", "DO", "AI", "AO", "BI", "BO"). A time switch, a twilight switch or an emergency stop on a board stay part of the distribution.
  • nfc15100.heating counts every item: three 1.25 kW heaters on 16 A were read as 1.25 kW.

Drawings: multi-line

  • Star-delta starters: the conductors W2 U2 V2 of the delta contactor go down to the motor, drawn with its six terminals (U1 V1 W1, W2 U2 V2), are carried by its cable in the wire lists and take room in the starter's column. They were drawn under the contactor, wired to nothing, with the motor on three terminals, and could be written on the board frame.
  • Converters: an inverter fed in DC (PV array, battery) gives the AC conductors of the installation at its output (its L+ and L- went on to the AC loads); below an inverter/charger, a busbar or board with no system stated that feeds only DC ways (a battery busbar) is on its DC side, with L+ and L-; an inverter whose children are all on its DC side keeps its AC output when a power link leaves it; a DC link to an inverter/charger or a UPS lands on its DC pair instead of being left out. The converter symbol shows what it is fed with and what it gives (= ~, = =).
  • Devices connected in parallel are drawn on taps beside the conductors, not as a box across all of them: voltage transformers and indicators, surge limiters, neutral impedances, insulation monitors and earthing switches (to the PE, else an earth symbol). A residual-current toroid is one ring around the live conductors.
  • Poles: a 1P or 3P device switches as many live conductors as it has poles, the phases first (a 3-pole contactor on a phase and neutral circuit switches the neutral too; a 1P device on a DC line is on L+); a thermal overload relay without poles acts on the phases only.
  • Drives and controllers feeding three-phase equipment give it three phases: a drive fed in single phase when anything below it is three-phase, an electronic speed controller fed from fewer than three phases or from DC (U V W at the motor, drawn 3~ in the single-line view).
  • Split-phase supplies (100/200 V, 120/240 V): a 2P device feeds a phase-to-phase circuit without the neutral unless something below it uses the neutral; a load's un_V tells which. These rules apply only below a split-phase supply (a three-phase motor elsewhere in such a document was drawn on two phases).
  • A conductor starts at an earth symbol only when it is the PE at the main earthing terminal: the live conductors of a document starting with a busbar, a board or a converter arrive on open leads from above, each with its name (they hung from earth symbols). The transformer star point is earthed in TN-C, TN-C-S and TT drawings, as in TN-S, never in IT.
  • With the conductor colours, the leads of a surge protector and of an earth electrode are drawn in the colour of their conductor (they were black).
  • The socket type is written under a socket, after its number of points; the tag is no longer repeated at the start of a device label ("-KM1" over "-KM1 water heater").

Drawings: single-line

  • Inverters/chargers and UPS have separate sides: the AC input on top, the DC terminal on the left, the AC output at the bottom. The grid, PV array and battery of a hybrid inverter landed on one point of its left side, forming a rectangle that read as a frame; now an AC infeed lands on top, battery, PV and DC board infeeds on the DC terminal (joined there with a junction), a link toward a changeover switch or an AC board leaves the output, and control and data links end on the right side or the top of the body. An inverter first in the tree with only batteries or PV below it draws them on its DC side. An inverter fed from the AC side is drawn ~ over =; a power supply fed from a DC line is drawn as a DC/DC converter.
  • Links: a link leaves a device by the side facing the other end, so a meter's lead no longer draws a dashed rectangle round the incomer that read as a board frame, and two interlocked contactors are joined on one side as a bracket; a link never takes the channel of another link (the two dashed lines read as one solid conductor), never runs on a busbar or right beside it, and is rerouted with more corners when that is clearly better. A standby supply reaching the side input of a transfer switch taps its busbar where it crosses the fewest feeders and is drawn, with its text, beyond the feeders passing by (it crossed every feeder of the section).
  • Power links join conductors: a power link from a conductor ending on an outgoing arrow (a generator feeding a busbar) starts on that conductor with a junction dot; a device in parallel after another (a surge arrester after its fuse) lands on the conductor below it, not on the side of its body, where it read as a bypass.
  • Three measure or data links or more between one device and others on its sheet are drawn as one trunk with a tee tap to each other end and a junction dot at each tee; they were a stair of dashed runs about 1 mm apart, loops round the incomer and round each feeder. A label shared by all the links is written once on the trunk. The links of a controller or a PLC, links naming a terminal and links to another sheet are drawn as before.
  • PLCs: every link leaving a module gets its own channel below it, the module widened for its wires (one about every 2.6 mm; past eight links they ran on one another), with the channel ("2.1") written up its wire under the module. Where the widened modules would make the sheet smaller, the wires are drawn closer instead. A link to another sheet leaving a channel writes that channel by its stub, and the leads to those stubs leave from under the modules (they were drawn alone, joined to nothing); a safety relay with unlabelled links to other sheets is drawn about 3 mm per stub instead of 5 mm. Auxiliary devices read or driven by a channel are placed under the band of the channels, never inside it, above the PLC or in the column of a device's off-sheet stubs; the band goes down under a device hanging into it; an auxiliary device goes inside the frame of its partner's board when there is room. The label of a link read by a channel goes near the device, not among the wires. Terminal numbers named on a device that is not a PLC module (from_port / to_port on a safety relay, a controller) are drawn. In multi-line views with auxiliaries, a link leaving a channel for another sheet no longer reserves a drop under its module.
  • Earth: an earth link never ends on the power path. To a board it ends on an earth terminal inside the board's frame (it ended on the busbar or on the incoming conductor), to a busbar drawn alone beside its end, to an inverter on the top of its body. An earth bar or electrode inside a board is that board's earth point, joined by a short lead; one in the power tree is on the protective conductor only (no line from the busbar that read as the bars earthed).
  • No conductor lead ends in nothing: a device outside the power path (a meter, a controller, a battery reached only by links) has no conductor tails, the first node of a document no incoming lead, a node feeding nothing no open output stub, and a way with no load ends on a small free terminal instead of a filled arrow that read as a reference to another sheet.
  • Conductor marks: one phase and the neutral is always one stroke and "+N" ("L1+N", also below a two-pole device, where the circuits take its two conductors); no "+N" on a line without a neutral (a three-pole device on a 3P network, single-pole circuits of a three-wire supply); the phase is taken from the node above that states one (a group RCD on L2 marks its circuits L2+N); a mark stops at a converter (a PV array behind a 4-pole device was marked 4); the supply line carries the system declared on it, else the installation's, and a transformer secondary its own, else its vector group.
  • A transformer whose neutral is earthed shows an earth. A protection relay, an instrument transformer or an earthing device alone on a way of its own has its column in the circuit table. The cable designation written by the author is shown with its composition beside its device ("XYZ-1 3G10"), as in the multi-line view.

Drawings

  • Boards: the frame of a board no longer encloses the equipment at the far end of its outgoing cables (an inverter, a UPS, a transfer switch, another busbar, a transformer fed above 1000 V, or a local isolator in front of them): they are drawn below it with what they feed (SPEC §3.1). A board feeding sub-boards ends after its own last way (its frame ran over the whole width below it), its frame encloses a symbol wider than its column and goes down round the off-sheet stubs of its devices, and a board in a standby supply drawn beside its changeover switch is framed and named.
  • A dashed signal link (control, interlock, trip, measure, key) is interrupted where it crosses a conductor, which is drawn whole, so the crossing no longer reads as a connection (not across a bundle of multi-line phases).
  • A generator whose line leads only through switches and protections to DC equipment is a DC machine, drawn "G =" with L+ L- in both views (it was "G 1~" feeding the DC equipment).
  • A device declared for direct current (dc: a surge protector, a switch-disconnector) directly under an inverter is on its DC side (a DC surge protector beside the PV arrays was drawn on the AC side, the inverter "=" over "~").
  • A spare way with no device (spare without in_A or poles) is a free space, drawn dashed without a conductor mark (it was a conductor leaving the busbar with no protection).
  • Identical items drawn once (count) show how many: x 12 under the tag of a device, 3 x 2.2 kW under a load in multi-line drawings, and a count row in the feeder table when the document has such items.
  • Outside the status colour mode, a node of status future, and what inherits it, has "(future)" added to its label (it was drawn as existing).
  • Device texts: the label of a breaker, fuse or RCD feeding one circuit is drawn when nothing else says it (what the user wrote there was lost when the load had a label of its own, and always in multi-line drawings), including the device feeding a spare way. In single-line drawings, a characteristic is left out beside a label only when the label says it word for word ("16 A" was dropped beside "116 A"). A rating of 0 prints nothing (it printed "0 A" or "C0"), and a breaker's curve is kept beside a label holding its letter inside a word.
  • Feeder table: the residual current of an RCBO or RCD goes in the RCD row only, written "30 mA type A"; the powers of one row share their unit ("0.6 kW" beside "3 kW"); a feeder with no protection shows the rating of its contactor or impulse relay; the column of a source with nothing below it is left out when empty.
  • Title block: the voltage gives both voltages when uln_V is stated and the system has a neutral ("3P+N 230/400 V"); the Standard cell stays empty instead of reading "core"; a value too long for one line goes on two lines, and one reduced to the exact width of its cell is no longer cut by a rounding error. The "Notes" title is left out when there is no note.
  • An interlock declared electrical, mechanical or removable_link is written "interlock K1", not "key K1".

Sheets and references

  • Drawing sets: a tie or transfer link whose ends are on two sheets is drawn at both ends, with a stub naming the other end and its sheet (it was not drawn). A board drawn on its own sheet names the sheet of the device feeding it, and that device with its board ("from =SA, -Q1 (sheet 1)") when its sheet holds another device with the same tag. Installations side by side drawn one per sheet take the name of their board, else the title of the drawing (not the label of their source). Of two boards as wide, the one later in the document goes to a sheet of its own, so the sheets keep the order of the document.
  • In multi-line drawings, a busbar too long for one sheet shares its ways evenly (27 ways: 9 on each of three sheets, not 13, 13 and 1). A busbar continued on another sheet keeps the frame of its board there, and the continuation is named after the board ("TD (cont.)", "TD, -ID2 (cont.)") in both views.
  • An off-page reference whose target is a node id prints that node's tag ("→ -S9"), not the bare id. The sheet reference of a link to another sheet is written first, beside its arrow, kept off frames; its label is never left out (on two or three lines, else in a free place with a leader). Off-sheet stubs stacked beside a device are attached to it, earth stubs on a riser with junction dots, the others each with its own lead, their arrows in one column. A reference in the feeder table whose printed number is longer than planned is drawn a little smaller to stay in its cell.
  • A long list of auxiliary devices linked to nothing, drawn in one column far taller than the sheet, is drawn in several columns.

Readability

  • Texts are kept off conductors, symbols and one another: a link label with no free place along its link goes on up to three lines, else in a free place with a leader square to the link; the text of an off-sheet stub with no free place beside it goes near it with a leader; a device label keeps 0.4 mm from the symbol in the next column; the off-sheet stub texts of a device push the next column right (only where the sheet keeps its scale); a device with stubs to other sheets is placed with room for their texts; a multi-line label keeps off the triangle of a mechanical interlock; no link label is written on the switch of a bus tie.
  • Frames are no longer drawn through a text: the edge of a board, enclosure or view frame moves past it, and the coupler between two boards side by side gets the room its text needs. A view frame and an enclosure round the same devices are one frame with both labels. A board's name is no longer written across its incoming conductor.
  • Text widths are measured with the advance width of each character (the widths of the PDF font), so boxes, columns and texts fit what is drawn: wide capitals, Cyrillic letters and arrows were wider than measured. A box widens for the text written in it (an impulse relay coil, a controller box with a short CJK text). Every text cut to fit ends with an ellipsis, by one rule.

  • Cable captions say each part once: a cable whose composition already counts its runs in parallel ("cores": "4x(4x1x240)" with "parallel": 4) was written 4x(4x(4x1x240)) beside its device, in both views and in the document outline; it is now written 4x(4x1x240). A designation that already gives the composition ("designation": "XYZ-1 5G6") no longer has it written a second time after it.

  • Single-line drawings: a dashed link from a device above a board to one inside it (a meter's tariff contact to a contactor under a feeder) ran down beside the board and across it just below the breakers, crossing every feeder; it now comes down into the board across its busbars, drawn with a gap there, and crosses no feeder. A solid power link still keeps off the busbars it would read as a tap of.

Languages

  • Drawings and rule findings in Dutch (nl), Japanese (ja, with the usual terms of Japanese panel drawings and the Japanese forms of the kanji in PDF and SVG), Croatian, Serbian and Bosnian (hr, sr, bs, Latin script) and Serbian in Cyrillic (sr-Cyrl), each with its practice's terms and decimal comma where used. Rule messages in Italian, Polish and Turkish too. Validation and command line messages stay in English.
  • The surge protector type ("Tipo 2", "Typ 2") and the split-phase system in the title block are written in the language of the drawing.

Speed

  • Large drawings are drawn several times faster, with the same drawings: the layout places labels and routes against an index of what is already drawn, costs routes on the obstacles near them, plans the sheets once and measures each text once. Multi-line views, drawn without the auxiliary devices, are much faster too.
  • Optional compiled link router: pip install "uniwire[native]" adds uniwire-native (Rust 1.83 or later to build), which runs the search of the link router many times faster with exactly the same drawings. Without it, when it cannot be loaded, or with UNIWIRE_NATIVE=0, the pure Python search is used, as before.

Exports, PDF and SVG

  • I/O list and terminal strip table: uniwire io FILE gives one row per channel of each PLC I/O module, connected or spare (slot, DI / DO / AI / AO, address, label, the device linked and the terminal it passes through); uniwire terminals FILE [--view ID] one row per terminal of each terminal block, with what arrives and leaves (and the wire marks of the view). Also io_rows, terminal_rows, io_csv, terminals_csv in uniwire.exports, and the wiring tool (what='io' or 'terminals').
  • PDF: the package ships a font, Liberation Sans (SIL Open Font License 1.1, see NOTICE), and every PDF is written with it, the same on every system: Cyrillic, Polish and Turkish letters came out as black boxes and "IΔn" as "IDn" where Arial was not installed (the web editor, slim containers). Every CJK character of a text is drawn with the CJK font when some are, and an arrow the font lacks ("⇄") is written in ASCII ("<->").
  • SVG: each sheet states the language of the document (lang, xml:lang), the printed sheet number (data-uw-folio), and each link drawn on a trunk data-uw-trunk. API: render_views(doc, views, counts), drawing_set_findings(counts), render_pdf(..., findings=[]).

Web editor

  • Large drawings are drawn several times faster: the editor loads the compiled link router built for its Pyodide release (packages/uniwire-native/build-pyodide.sh, served with python viewer/build.py --native), and draws in pure Python as before when it cannot be loaded.
  • The sheet tabs show the sheet numbers of the drawing set, and the rule findings are in the language of the document when uniwire has it (they were in French or English only).
  • The drawing no longer jumps while the editor starts: the sheet tabs keep their own row and the view and colour selects stay on the controls' row. The page carries its full title and a heading for screen readers.

Assistants

  • MCP server: a tool accepts, as its document, the editor link a tool returned (viewer_url): a long #doc= link carries the document, a short #d=<id> link reads it from the server's store. Such a call was refused.
  • Reference card: multi-line views are the power diagram (auxiliaries: true adds the auxiliary devices), and meta.lang is the language of the labels written in the document, which the texts drawn by uniwire follow.

0.1.8 (2026-11-02)

  • Single-line drawings: a link whose route passes through a text or a symbol, or goes far round, is routed with as many corners as needed when that is clearly better, and may leave a device by its other side; a standby supply reaching the side input of a changeover is routed round the busbars, feeders and texts on its way (before, it ran straight across them, possibly along a busbar).
  • Single-line drawings: the texts of a bus coupler go below it when a link already passes above it.
  • Multi-line drawings: a device text too wide for its place goes on two lines at the usual size instead of being drawn smaller and cut short.
  • DC lines: a battery, a PV array, a DC/DC converter and a power supply with a DC output start a DC line even when no system is stated: the devices below are marked with two poles (never +N) and a motor there is drawn M =.
  • Documents: a text too long for a field that shows only a few characters (symbol_text) is read short instead of refused, reported by core.normalized: without its spaces when that fits ("L1 L2 L3" read as "L1L2L3"), else the initials of its words when they are all words of letters ("Air conditioner" read as "AC"), else its beginning.
  • Drawings: the box of a load is as wide as its symbol_text (a six-character text ran over its sides).

0.1.7 (2026-11-01)

  • Docs: uniwire is in ChatGPT's plugin directory (uniwire in ChatGPT); the hosted server's logging is described as it is (the request and the caller's address in the security logs, one year).
  • Rules, new core.phases-feeder (warning): a three-phase load (phases: 3) fed by a single-phase circuit (1P+N or 2P protection, 3G cable, single-phase supply); a drive or a converter in between makes its own phases.
  • Rules, iec60364: the current-carrying capacity of a cable is no longer compared with a protection on the other side of a converter (the AC breaker of an inverter against the DC cables of its strings).
  • Documents with unambiguous mistakes are read instead of refused, each fix reported by core.normalized: a number written for a text ("range_A": 10 read as "10"), and in an object, a single unknown field beside a single missing required one, read under the missing name ({"rev": "A"} in meta.revisions read as {"index": "A"}).
  • An unknown field is reported with the fields that can be written at that place, and the required ones missing.
  • Faster start: the node models are no longer built one by one on import (import uniwire and each command start about four times faster).
  • Multi-line drawings: the device carried by a link is drawn on the verticals of the link when its horizontal run is too short for it (before, it was left out); a link to a load reaches the load's terminals instead of passing below it; a bypass parallels the live conductors, never the PE; a link leaving a conductor that goes on is marked with a junction dot.
  • Multi-line drawings: an odd x core count ("3x") is taken to include the PE only as a guess, after what the node states (a motor's phases), and never when the PE has its own section ("3x", 95 mm², pe_section_mm2 50: three phases and a PE); a three-phase motor is no longer drawn on two phases.
  • Drawings: a cable given by its section alone is written with its unit beside its device (10 mm², not 10); the table keeps the bare number under its heading Cable (mm²).
  • Drawings: a motor that does not state its phases is marked as its feeder (1~ on a single-phase circuit), in the single-line and multi-line diagrams.
  • Multi-line drawings: the frame of a board holds a link between two of its devices (a bypass and its contactor), without reaching into the column on its left.
  • Multi-line drawings: a sheet drawn too tall to stay readable (below min_scale) sends a branch to a sheet of its own (what a protective device feeds, the device staying with its board), as a sheet too wide already did; a board that is the whole drawing is no longer sent to a sheet of its own, which left a first sheet with only the supply; a transformer at the head of a sheet names where it is fed from.
  • Drawings: at the stub of a link to another sheet, the sheet reference is always written and the link's label only where it is free (it is also written at the stub on the other sheet); the stub is drawn longer when that gives its reference a free place. Labels are no longer written across symbols and frames there.
  • Single-line drawings: the tag of a device carried by a link stays beside its symbol (the nearest free place a few millimetres from it, else beside it anyway) instead of going as far as the text of another device.
  • Drawings: the unit of a setting range is written only after numbers (9-13 A); a range given in words ("to confirm") is shown as written.

0.1.6 (2026-10-30)

  • Drawings: long texts are fitted in time proportional to their length (wrapping on several lines, cutting with an ellipsis, title block cells); drawings of usual documents are unchanged.
  • MCP server, public mode: every tool result is bounded (30,000,000 characters of JSON, normalize 4,000,000), checked in the worker process.
  • MCP server, short links: ids derive from the content and a secret key of the store (DIR/.key), so that the link of a document cannot be worked out from its text; existing links keep working. Only diagrams are stored, the size of the store is checked at each write, /pdf and /svg drawings are cached in memory, a deletion sent by a page of another site is refused, and the error page of a PDF link no longer quotes the document.
  • uniwire-mcp --http warns when it listens on another address than loopback without --public.
  • Web editor on uniwire.sh: each PDF export adds one to an hourly total kept by the site (nothing else is sent).
  • Web editor: a document that takes more than a minute to draw stops the engine, which starts again, instead of leaving the page waiting; it is drawn again once edited.

0.1.5 (2026-10-30)

  • Translations reviewed in every language: wrong meanings fixed (German "converter", Chinese and other languages on RCD selectivity, which now says to use a selective type S device, the French messages of the vde0100 profile on charging points), trade terms made consistent within each language (one term per device), labels shortened to fit their cells, Portuguese made consistently Brazilian (NBR 5410 vocabulary), Russian number agreement and no dash. The page "About this document" no longer names the button of the web page, which is in English and French only. --lang lists the ten languages. Web editor: the PDF error message names the current menu entry.
  • Drawings: a load power below 1 kW is written in watts (16.2 W, 500 W), from 1 kW in kilowatts; small DC loads no longer round to 0.016 kW.
  • Drawings: a DC converter shows its output voltage (un_V) and its current (in_A).
  • Drawings: the text beside a device stops before the symbol on its right, however wide it is (converters side by side no longer touch the next one).
  • Checks: a battery at the root of sources, the only source of a DC system (vehicle, boat, off-grid site), may feed the installation: no core.terminal-node warning.
  • Checks: core.no-cables (info) when a profile that checks cables is active but no circuit gives its cable size, so that an empty result is not read as cables checked.
  • Drawings: a link label with no clear place on one line (a short link) goes on two lines, clear of the symbols; a wrapped line no longer starts with a separator (a dash, /, :).
  • Drawings: a device text that repeats its label in another case (Type 2 under … type 2) is not repeated.
  • Reference card for assistants: socket-outlets are entered as socket nodes even on a shared circuit (so the RCD rules see them), and a feeder continued elsewhere ends on an offpage node, not a spare.
  • Drawings, dense control circuits (many auxiliary devices and links, several of them reaching one controller):
  • a controller reached by three links or more is drawn taller, with one point per link on its sides (on the right for the devices to its right), in the order of the other ends: its links no longer share one route;
  • its links to other sheets end on stubs along its side, and its column leaves room on its left for their texts;
  • each auxiliary device is placed with room for its link labels on the side facing its partner, and a label goes near the end of its link where fewer links meet;
  • a link label with no clear place near either end goes in the nearest free space, joined to its link by a thin leader, instead of over a symbol or another text;
  • the text of the last device of a row, with nothing drawn to its right, is no longer reduced or cut to fit its column.
  • Drawings: an AWG size is no longer dropped when the composition holds the same digit (6G with #6 gives 5-#6+G, not 6G).
  • Drawings, multi-line view: a characteristic the label already gives (25 kVA in 25 kVA unit) is not repeated.
  • Drawings, multi-line view, the same for a controller many links reach: its box grows with its links, one point each a lane apart, its column leaves room on its left for their labels and stubs (no longer written across the conductors of the next feeders), and no auxiliary device is put in that room.
  • Drawings: the texts of an off-page stub end before the point of its arrow.
  • Drawings, sheets: a board wider than a sheet below another board goes to sheets of its own, so that the board feeding it keeps its ways together on one sheet (a main board of four ways feeding two large boards was cut way by way over three sheets).
  • Drawings: the texts at the ends of a busbar continued on another sheet ('continued from', 'continued on') are placed clear of each other and of the name of the board: beyond the end of the busbar, or below it, when the space above is taken.
  • Checks, iec60364.iz and iec60364.iz-estimate: Iz now follows IEC 60364-5-52, as formulas a * S^m that never give more than its values (registry/data/iz_iec60364.json, uniwire.registry.iz_iec60364()), instead of the Spanish GUIA-BT-19 tables at 40 °C. Aluminium in air, PVC in the ground and method D2 (buried directly) are now covered. The ambient temperature corrects Iz at any value from 10 °C to 60 °C (PVC) or 80 °C (XLPE), by the heating of the conductor, instead of two steps at 30 and 40 °C. In the ground, without ambient_C, 20 °C and 2.5 K·m/W, the IEC reference (the Spanish tables took 25 °C and 1.5 K·m/W). registry.iz_tables() still reads the Spanish tables, no longer used by the rules.
  • Tests: the readability audit also counts texts written over a symbol, texts crossed by a link, link texts written across a conductor, texts reduced to fit, and two texts run into each other over a few letters however small their overlap; a set of dense documents (tests/dense_docs.py) holds the layout to these counts.
  • Drawings: a device text too wide for its room (a surge protector beside a feeder) goes on more lines at its usual size before it is reduced; it is reduced only when no split fits.
  • MCP server (--http): a PDF link opened in a browser that cannot be served (expired, deleted by a link holder, or a document that cannot be drawn) shows a short page in the browser's language saying what happened and to ask the assistant again, instead of a line of English text. Scripts and assistants still get the plain text.
  • Format 1.1: a cable may give the conditions that lower its current-carrying capacity: grouped (circuits or multicore cables laid together), arrangement (how they lie in air), supports (stacked trays or ladders), spacing_m (between circuits in the ground), soil_resistivity_K_m_W and third_harmonic_pct. A 1.0 document is a valid 1.1 document.
  • Checks: iec60364.iz and iec60364.iz-estimate apply the grouping, soil resistivity and third-harmonic factors of these fields, as formulas never above the factors of IEC 60364-5-52 (registry.iz_iec60364()["factors"]); the message lists them. Beyond their range (more than 20 circuits in air, 6 in the ground, a soil above 3 K·m/W, harmonics above 50 %), Iz is not checked (info).

0.1.4 (2026-10-28)

  • PDF: a page "About this document" may follow the sheets. It is not a sheet of the diagram (no folio number): the rule profiles applied and the number of findings, the scope of automatic checks, where the online copy is and how to delete it, and how to write to the uniwire team, with a QR code. Every address on it is a link. In the 10 languages of the drawings. The hosted server adds it to GET /pdf/<id> (?about=0 leaves it out), the web editor offers it with a box in the Download menu (remembered by the browser), and the command line with uniwire render -f pdf --about (--doc-id names the online copy); render_pdf(..., about=About(...)).
  • PDF and SVG: web addresses can be links (groups of class uw-href); the drawings can hold filled outlines (Path, used for the logo).
  • Web editor: a short link whose document was deleted says so.

0.1.3 (2026-10-28)

This release also ships the changes of 0.1.2, which was not published on its own (see below).

  • Cable texts: a protective conductor run beside the cores (pe_section_mm2 with a composition such as 4x) is written with them, 4x25+PE16, in the drawings, the feeder tables, the bill of materials and the cable lists; it was left out, so that a cable with its own PE read as a cable without one.
  • Hosted MCP server (--store): whoever holds a short link can delete its document before it expires (POST /doc/<id>/delete, never a GET, so that link checkers cannot delete anything). The links of a deleted document answer 410 instead of 404, so that the web editor and the PDF link can say it was deleted; storing the same document again (a new request from an assistant) makes it available again.

  • Multi-line view: the auxiliary devices (devices) and the control, interlock, trip, measure, data, key and earth links are drawn, placed and routed as in the single-line view (beside the node they are linked to, clear of the conductor bundles and the symbols), with a band above the feeder cables for their channels; a PLC is drawn with its modules, its links leaving from the module they use (port label); a link whose other end is on another sheet ends on a sheet reference.

  • Multi-line view fixes: an earth or equipotential bar in a board is on the PE only (it took every conductor), drawn with its symbol; a single-phase transformer has a single-phase secondary (two unearthed conductors at 50 V or less); a power link from a source with a PEN feeds the neutral of a target with N and PE (the genset neutral of a 4-pole changeover was missing); a current transformer is a ring on each phase, a connector a socket and plug on each conductor (no box repeating the tag); a mechanical interlock carries its triangle (it was missing in PDFs), between the delta and star contactors of a star-delta starter too. Split-phase (120/240 V): a "2P" breaker switches L1 and L2, the neutral going straight through, and a 240 V motor takes L1 L2 (L2 was lost). The PEN splits into N and PE at the entry of a board declared TN-S or TN-C-S (residual-current devices took the PEN). A genset of a TN-C-S installation has its own N and PE (its 4-pole breaker was drawn with 3 poles). An inverter or UPS at the head of the tree takes its AC input on top (it landed on its backup outputs). A power link carries the PE of its cable (solid, never drawn open) and its label, runs below the bars of a sub-board beside its source, and reaches the outputs of the last device of a board from its right (it wound round the device). An equipped spare way is its grey device with its rating, not a load fed straight from the bars. A control link leaves the operating line of a contactor by turning down at once, never as its continuation. A drive fed in single phase delivers the three phases of its three-phase motor (U V W, it delivered one phase and the neutral); a DC motor is marked "="; the PE passes beside a transformer to its earthed secondary side, or ends on the earthed enclosure when no PE leaves it (it ran into the windings); the cable of a feeder is no longer written on the run behind a drive or converter; the conductors of a power link stay solid when its device shows the normally open contacts.

  • Single-line view, feeds between trees: a tree that only adds a supply to another one (a genset, a charger, a storage converter whose infeed lands on a busbar of that tree) is drawn beside it, whatever its place in sources; a link between two trees with a third tree between them is drawn as an interrupted line, a stub at each end naming the other end, instead of a run across the sheet; several feeds landing on one busbar each get their own tap on top of it, routed on separate channels without crossing (the second one ended on a stub of conductor that did not exist), the board frame enclosing the taps.

  • Single-line view, sheets: several trees too wide for one sheet are cut into groups of whole trees that each fit (the fewest sheets, then the fewest links between them, each ending on an off-page reference), before any board is taken to its own sheet; such a sheet no longer shows an incoming feed, and a bus tie between two sheets ends on an off-page reference at each end (it was not drawn). The board taken to its own sheet is the smallest one that makes the sheet fit (it was the widest: a first sheet could hold only the incomer, the next one only the main board), and a main board as wide as the whole sheet stays with its supply, its busbar going on over the next sheets under the board's name (the first sheet held only the supply; the continuation was named after the device at the head of the busbar, a meter for instance). The output of a power supply with nothing drawn below is marked with its two poles (it was marked with its input, 'L1+N' under a 24 V DC supply). An instrument above a busbar (measure link) is connected straight down onto it; auxiliary devices are placed off the channels of the feeds tapping a busbar, and these channels pass below an off-sheet reference hanging over them. Feeder table: the cells of a column stay under its feeder when a long board name widens the drawing (they were centred between the feeders), and a board with a single outgoing (a panel fed through a transformer, an enclosure around one load) shows the protection and cable of the feeder above it (its cells were empty). A description too long for its cell goes on 2 or 3 lines before its text gets smaller (it shrank to a few tenths of a millimetre).

  • Single-line view: a control or data link between two loads too close for its label runs under the loads, where the label has room (it was written over the symbols).

  • Profile iec60364: rule iec60364.rcd-30mA (IEC 60364-4-41:2005+AMD1:2017, 411.3.3 and 411.3.4), socket-outlets up to 32 A and, in dwellings, lighting circuits protected by an RCD of at most 30 mA, except below the isolation transformer of a medical IT system; left to nfc15100 and vde0100 when the document declares one of them. Rule iec60364.iz-estimate: a cable without its material, insulation or installation method was not checked at all; its current-carrying capacity is now estimated (copper, PVC, the most favourable method in air, 30 °C) and one info finding lists the cables estimated. Example 27 draws the RCBOs of its treatment rooms. Rule iec60364.iz takes the cable's ambient_C (30 °C: the values brought back to 30 °C; up to 40 °C: the values at 40 °C; hotter: not checked, said in an info), and reads D1, the IEC name of cables in ducts in the ground, as D-duct; without ambient_C its message says that 40 °C was assumed (a cable at 30 °C was checked at 40 °C).

  • Rule core.terminal-node (a PV array, a battery, an SPD or an earth electrode with children) says how to draw it: below the device that connects it, the power may flow both ways.

  • PLC annotation: the protocols are cut on whole names, with an ellipsis ("Modbus TC" was printed).

  • Rule checks: when no rule profile applies, an info finding core.no-profile says that only the consistency of the document was checked (an empty result read as a checked installation); for a standard no profile covers (NEC, for example) it says that the protections, cables, residual-current devices and earthing were not checked against it.

  • North-American documents (NEC / CEC): cables are written with their AWG / kcmil size whenever it is given ("2x#6", "3G" with #12 written "2-#12+G"; the section in mm² was printed), and residual-current protection is written "GFCI" (6 mA or less) or "GFPE" instead of an IEC type ("5mA type A" was printed for a GFCI).

  • An infeed link to a device that feeds nothing (the back-feed breaker of a PV inverter) lands on its output terminals, in both views (it arrived on the busbar side). A label without a tag goes on two lines rather than being cut when the room beside the symbol is short.

  • Units: a number and its unit are written apart everywhere ("100 A", "20 A 30 mA", "C16 30 mA", "gG 32 A", "6 kA", "Ir 63 A", a spare way "125 A"), in the drawings, the circuit tables and the bill of materials; the ratings of protective devices were written "100A" and "30mA" beside "200 A" and "250 kVA". Curve designations ("C16") are unchanged.

  • Examples 21 and 29: the feeders of the refrigeration board and of the smoke-control board carry a neutral (their 1P+N circuits need one).

  • Drawings in Spanish (meta.lang "es") and Simplified Chinese ("zh"): title block, notes, legends, table headings, type names and the short texts in symbols, with IEC 60050 terms (GB/T terms for Chinese; neutral terms where Spain and Argentina differ). Spanish numbers take a decimal comma. Messages stay in English.

  • Drawings in German (meta.lang "de", "de-AT", "de-CH"...): title block, notes, legends, table headings ("BMK", "Stromkreis"), type names and the short texts in symbols ("FU", "SPS", "USV"), with the terms of DIN EN 60617 and IEC 60050-826 practice. German numbers take a decimal comma. Messages stay in English.

  • Rule profile vde0100 (German installations, DIN VDE 0100): 30 mA RCD for socket-outlets up to 32 A and for the lighting of dwellings (410), circuits of bathrooms (701, a fixed water heater exempt), charging points with their own circuit and RCD of type B or A/F with 6 mA DC detection (722), surge protection (443/534) and PEN cross-section (540). Combine it with iec60364. Example 06 uses it. A document following DIN VDE 0100 without a profile is pointed to it.

  • Rule findings in German, Spanish, Portuguese, Russian and Chinese (UNIWIRE_LANG), with the terms of each practice (RCD/FI, diferencial, DR, УЗО, 剩余电流保护器); CLI and validation messages stay in English.

  • Drawings in Portuguese (meta.lang "pt", "pt-BR", "pt-PT"): title block, notes, legends, table headings ("Identificação", "Circuito"), type names and the short texts in symbols ("DR", "DPS", "CLP"), with the terms of ABNT NBR 5410 practice. Portuguese numbers take a decimal comma. Messages stay in English.

  • Drawings in Italian (meta.lang "it", "it-IT"): title block, notes, legends, table headings ("Sigla", "Circuito"), type names and the short texts in symbols ("INV", "PLC", "UPS"), with the terms of CEI 64-8 practice. Italian numbers take a decimal comma. Messages stay in English.

  • Drawings in Polish (meta.lang "pl", "pl-PL"): title block, notes, legends, table headings ("Oznaczenie", "Obwód"), type names and the short texts in symbols ("PCZ", "PLC", "UPS"), with the terms of PN-HD 60364 and PN-EN 60617 practice. Polish numbers take a decimal comma. Messages stay in English.

  • Drawings in Turkish (meta.lang "tr", "tr-TR"): title block, notes, legends, table headings ("Etiket", "Devre"), type names and the short texts in symbols ("SRÜ", "PLC", "KGK"), with the terms of TS HD 60364 and Elektrik İç Tesisleri Yönetmeliği practice. Turkish numbers take a decimal comma. Messages stay in English.

  • A cable written in a device text comes after the device's own lines (settings, poles, vector group) and never replaces one; a composition ending with its section ("4x35+PE16") is not followed by the section again. "Safety circuit" is not repeated on every feeder of a safety board, nor a data link protocol already in a device text. Sheet references between the views of one PDF point to the right sheet numbers.

  • Circuit table: "(upstream)" no longer marks the group RCD of a board on the columns of the boards it feeds on other sheets; a tag is prefixed with its board only when the same tag comes from different boards.

  • The surge limiter's "L" no longer runs into its text; bold CJK text is drawn bold in PDFs.

  • Formats: thousands grouped from 10 000 ("20 000 V"); phases separated ("L1-L2-L3"); the RCD type not repeated in the RCD cell when the table has its own row for it.

  • A busbar that has feeders is no longer drawn twice (a short bar on the incoming conductor and the busbar).

  • Circuit table: a tag found in two boards of the same table is prefixed with the board's ("PDU-A -Q1"). Chinese and Japanese descriptions are written upright, one character under another.

  • Information now shown: the drawing number (title block), the earth electrode resistance taken from an earth node, the setting of an overload relay ("Ir 48.5 A"), "Safety circuit" on the feeder of a safety service, and the protocol of a data link that has no label.

  • Cables the circuit table does not show (feeder of a sub-board, a transformer or an inverter, incoming cable of a board) are written in the text of the device feeding them ("5G10 15 m", "W7 5x6 38 m").

  • Multi-line view: a motor starter is drawn with contactor contacts; a reversing starter with its reverse contactor (phases L1 and L3 swapped, mechanical interlock), a star-delta starter with its delta contactor (to W2 U2 V2) and its star contactor.

  • uniwire render -f pdf writes every view of the document in one PDF unless --view or --kind is given; the sheets of a drawing set are numbered across its views (1 / 3, 2 / 3, 3 / 3).

  • CJK text (Chinese, Japanese) is wrapped between characters, not only at spaces: notes, title block values, frame labels and off-drawing targets stay in their cells. A device text too wide for its column goes on two lines before being cut with an ellipsis.

  • Russian: device type names (circuit table and elsewhere) and "тип" for the RCD type.

  • Small texts: an RCBO without a curve reads "20A 5mA"; transformer ratios in one unit where possible ("20 kV/400 V", "400/230 V"); a name whose label starts with its tag shows the tag once ("TGBT", not "TGBT TGBT"), and a device text no longer repeats its tag or a line already in its label; rule profiles named in the title block ("IEC 60364").

  • PDF: characters the font lacks are replaced (subscript digits by digits, clocks by a circle) or left out, never drawn as empty boxes.

  • North-American cables are written with their AWG / kcmil size when given, even with a section in mm² for the checks (unless the composition is written the IEC way, "3G" + mm²).

  • The title block of a board drawn on its own sheet shows that board's voltage and short-circuit current.

  • Fix: the breaker drawn for an equipped spare way has a stable id in the SVG (<spare id>.breaker).

  • Link routes: control, data and measure links keep clear of dashed frames and busbars, no longer share segments or run along a conductor, and leave a device by its left or right side, whichever gives the clearer route; boards get room at the bottom of their frame for these links. Several links landing on one input conductor get one point each.

  • An equipped spare way (spare with a rating) is drawn with its breaker, tag and rating.

  • Circuit table: a feeder shows its overcurrent protection (breaker, fuse) rather than an RCD or switch below it; a way of a small sub-busbar shows the breaker or fuse feeding it, with its own tag.

  • Off-sheet arrows carry their sheet reference or target drawing on the drawing itself.

  • Fix: a node text moved by a view's label_offset is now avoided by link routes and labels.

  • Rendering the same document again reuses its layout (a PDF after a check is drawn at once).

  • Standby sources on several transfer switches (one generator per switch) are drawn side by side instead of on top of each other, and on the sheet of their switch when its board has a sheet of its own; a link with no free route no longer makes the drawing fail (internal error, PDF refused): it is routed below its feeder, or left out.

  • Drawing of inverters and links: a PV string or battery way that also carries its surge protector, meter or insulation monitor stays on the DC side of the inverter (it was drawn on the AC busbar); an infeed link to an inverter or UPS at the head of the tree lands on its input, on top, the side being the DC terminal; a power link drawn as a plain line no longer runs along a busbar; links of different kinds no longer share one end point.

  • Frame labels (enclosures, view frames) too long for their frame are written on two or three lines between the conductors that cross the frame, the frame widening over free room if need be, instead of crossing a busbar or a conductor.

  • Circuit table: a spare way without its own rating, fed by its own breaker, shows that breaker (tag, rating, curve, poles); the columns were empty.

  • New example 53: office with a hybrid inverter, rooftop PV, battery and an essential loads board.

  • New core.scope finding (info): when a document describes control circuits (contactors or relays fed by a control power supply and switching nothing, coils, push buttons or signal lamps entered as loads), check says that uniwire draws power distribution and not control schematics, so that these circuits are only summarized. llms.txt and the assistants page state the same scope.

  • A main_breaker without idn_mA is drawn as a circuit breaker, no longer with the residual-current toroid and "IΔ" of a residual-current breaker (the multi-line view already did so).

  • Conductor-count marks of DC lines: a line behind a DC source, a DC box or a device declared dc is marked with its two poles, never with a "+N" neutral, whatever the poles of its devices (up to an inverter).

  • French messages write decimals with a comma ("disjoncteur 32 A sur 1,5 mm²"), like the drawings.

  • PDF: Chinese, Japanese and Korean texts are drawn with the CID fonts every PDF reader knows (they were missing before); Liberation Sans is used when installed (Linux), with the widths of Arial that the layout expects. The MCP server images install it.

  • New rule profile enedis (opt-in): connection of a low-voltage installation to the French public network, following the Enedis technical reference (Enedis-NMO-RAC_001E) and NF C 14-100, separate from nfc15100, which starts downstream of the service main breaker. Rules: enedis.connection (12 kVA at most in single-phase, 36 kVA in three-phase for a limited-power connection; monitored power and medium voltage above), enedis.agcp-setting (the service main breaker setting carries the connection power and cannot be below the subscribed power or above 60 A), enedis.agcp-rcd (500 mA residual-current service breaker recommended), enedis.production (injection and installed power limits in single-phase and three-phase, storage included, Enedis-NMO-RES_032E), enedis.service-cable (individual service cable: 30 m and 35 mm² aluminium) and enedis.decoupling (decoupling protection of production and storage inverters). The French examples on a Tarif Bleu supply declare it.

  • nfc15100 profile checked against the text that gives presumption of conformity (NF C 15-100 2002 with its 2005 update and amendments A1 to A5): the rules of dwellings now cite part 10-1 of amendment A5, which replaces part 7-771.

  • Fixes: the 30 mA protection of dwelling circuits and the minimum of 2 RCDs (now an error) are checked in three-phase dwellings too; lighting and socket points are added up per circuit; the circuits behind an RCD are counted through combs and boards, with count; the dryer no longer requires a type A RCD; a shared freezer circuit is a warning; outside dwellings, socket-outlets above 32 A no longer require 30 mA; a non-selective RCD upstream of other RCDs is an error in a dwelling.
  • New rules: nfc15100.circuit-section (section and protection of dedicated circuits), nfc15100.rcd-rating (rating of the 30 mA RCDs, warning), nfc15100.rcd-spread (lighting and sockets over at least 2 RCDs), nfc15100.spd-rcd (surge protector at the origin not behind 30 mA), nfc15100.agcp-rcd (500 mA at most, no adjustable sensitivity on a limited-power supply), nfc15100.earth-resistance (TT, 50 V), nfc15100.neutral-pole (no 1P breaker in a dwelling) and nfc15100.supply-section (link from the service breaker to the main board).
  • EV charging rules cite IEC 60364-7-722 / guide UTE C 15-722, which are not part of that text.
  • Examples 15 and 36: lighting and socket circuits spread over two RCDs; the reference card example and the quickstart use two RCDs.

0.1.2 (not published: shipped in 0.1.3)

  • Bill of materials: equipment without a product reference is grouped by type and main characteristics (new spec key, e.g. C16 1P+N 6kA, 40A 30mA 2P type A) and cables by type, composition and material (new length_m key with the total known length), instead of being left out. Rows with a reference are unchanged and come first; the CSV puts the characteristics in the description column. The utility's meter (fed directly by the grid) is not listed unless it carries a reference; sub-meters are.
  • MCP server: every tool parameter is described in the input schemas (document, language, view, rule profiles...), and the descriptions say when to use each tool and which one to use instead (validate vs check, list_types then type_info, bom vs wiring).
  • MCP server: tool descriptions say what each tool does, takes and returns; the guidance for assistants (which links to give, the conformity disclaimer, the workflow) lives in the server instructions only.
  • Web viewer: a link to an example that does not exist (?example=98) opens the first example with a message, instead of an empty editor.
  • Web viewer: clearer download menu: "PDF, all sheets" downloads the PDF, "Print all sheets…" opens the sheets for printing.
  • Web viewer: panning the drawing no longer selects its text; text is selected on purpose only (double-click a text, or drag with Alt/Option held).
  • Web viewer: the drawing shows at once, while the in-browser engine starts (10 to 25 seconds on a first visit): the examples come with their first sheet drawn at build time, and short links (#d=) with the first sheet drawn by the server (new route GET /svg/<id> of the hosted MCP server). The live drawing replaces it when ready.
  • Sheets: when a view gives no paper, the drawing goes on an A4 landscape sheet if it fits there at full size, else on A3 as before. A drawing that uses little of its sheet is enlarged, up to 1.25 (annotations of 2.5 mm), with the same scale for all the sheets of a view so that the text keeps one size; large drawings are still reduced to fit.
  • Battery symbol: the two cells are joined by a dashed line, with a lead below the last one and the + and − marked, so that it no longer reads as an earth symbol at small sizes.
  • Heating symbol: the last of the four strokes no longer goes past the right side of the box.
  • Single-line diagrams: an annotation is no longer cut with "…": its column widens as needed (the text may still be reduced, down to 1.5 mm), and a board's column widens to its name, so that board frames no longer cross their name or each other.
  • Multi-line diagrams: board frames keep clear of the switch blades and of the frames next to them.
  • Multi-line diagrams, TT and IT: the PE starts at the main earthing terminal of the first board, no longer at the incoming device whose cable carries a protective conductor; a board drawn on its own sheet starts its PE there, and the sheet that feeds it carries the live conductors only.
  • Examples 03 and 09: three-phase smart meter rated 60 A.
  • Boards fed from the same board are drawn side by side on one line (single-line and multi-line): their frames, names and first devices are aligned.
  • Inverters/chargers and UPS feeding both a DC side (batteries, PV, DC converters, DC boards, or a device feeding one of them alone) and an AC side: in single-line diagrams the DC side is drawn from a side terminal of the symbol, no longer from the busbar of the AC outputs; in multi-line diagrams the AC outputs keep the AC conductors and only the DC side gets the L+/L- pair, also when the inverter/charger is the source.
  • MCP server image: Python 3.14.
  • Tests: the worker pool tests start from a warm worker with a wider timeout (they failed on slow CI runners).
  • Web viewer and documentation: light by default, whatever the system setting; dark when the reader chooses it (the choice is remembered and shared with uniwire.sh).

0.1.1

  • nfc15100 profile: the rules of dwellings (part 7-771) apply only when installation.premises is dwelling or not set. For other premises the profile keeps the general rules (30 mA on socket-outlet and charging circuits, EV charging, selectivity) and the residential cable table becomes a warning to size the cable for its installation method (part 5-52, guide UTE C 15-105). The scope of check results says which rules applied.
  • Symbols redrawn to follow the international drawing conventions: socket outlet with protective contact, inverter with direct current top left, junction box as a circle with a dot, motor starter, variable-speed drive as a frequency converter, protective earthing on earth bars, "IΔ" on residual-current devices, "V" on voltmeters, photovoltaic generator, water heater. Converters draw direct current as a full line over a dashed one; UPS symbols carry the "UPS" label.
  • The MCP server announces its website and icon to clients.
  • Hosted MCP server: the tools that return links (validate, check, apply_patch, render, viewer_link) are annotated as publishing (not read-only, open world) when the server keeps documents for short links (--store).
  • Hosted MCP server: pdf_url is a plain PDF link (GET /pdf/<id>, drawn on the server and named after the document title) instead of an editor link that downloads the PDF; --pdf-base sets its prefix.
  • Web editor: files downloaded from a shared link are named after the document title instead of "shared".
  • PDF: the document title is the PDF title (shown by PDF readers and browser tabs), instead of the first sheet's.

0.1.0 (format 1.0)

First release of the uniwire format and of the uniwire Python library (Apache-2.0; specification text under CC BY 4.0).

  • Format 1.0: *.uniwire.json documents describing an installation as a power tree (sources, devices, loads) plus links for everything outside the tree; typed nodes (53 types), templates, views; published JSON Schema at https://uniwire.sh/schema/v1/uniwire.schema.json (specification).
  • Node types for utility supplies, MV/LV transformers, generators, UPS, PV, batteries, inverters, protective and switching devices, instrument transformers, protection relays, insulation monitors, busbars, boards, terminal blocks, loads, modular PLCs (ordered modules, roles, protocols, channel ports) and power supplies.
  • Common node fields (count, circuit, un_V, ib_A, normal_state, locks...), auxiliary devices outside the tree (devices[]), addressable enclosures (enclosures[]), key interlocks (interlocks[], locks[] on nodes and links).
  • Link kinds transfer, tie, bypass, parallel, infeed, earth, control, interlock, trip, measure, data and key, with optional cable, device and terminal / channel ports.
  • Structured product references on every node and PLC module; bill of materials as CSV (uniwire bom).
  • Validation with explicit messages (unknown fields, wrong units, broken references); any 1.y.z document is accepted.
  • Rule profiles: core, nfc15100 (French dwellings), iec60364 (cable current-carrying capacity from the GUIA-BT-19 tables), PLC consistency checks, interlock check.
  • Single-line diagrams: automatic layout, automatic sheet splitting with cross-references, circuit schedule, enclosure frames, title block, revisions and notes, top-down or bottom-up drawings.
  • Multi-line power diagrams derived from the same document: one line per conductor (L1, L2, L3, N, PE / PEN), one contact per pole, RCD toroids, PEN split, transformer windings, motors, busbars as one rail per conductor; uniwire render --kind multi-line for any document.
  • Colour modes per view: conductors (IEC 60445 or North-American colours), phase, source, status or voltage level, with palette overrides and a legend.
  • Wire marking (the part of UEP-0001 that format 1.0 can carry): marking rules per view, manual marks in cable.marks, cable tags on the drawings; CSV exports uniwire wires, uniwire markers, uniwire cables, and uniwire marks [--write].
  • SVG output with a documented structure contract (Python API); multi-sheet PDF with bookmarks and clickable cross-sheet references.
  • English and French rendering (meta.lang); CLI messages follow UNIWIRE_LANG.
  • Code-first API uniwire.build: installations as Python code (guide).
  • Command line uniwire: validate, check, render, bom, wires, markers, cables, marks, graph, normalize, schema, symbols, card, describe, patch, link, --version.
  • Terminal / connectivity-node graph derived from the document, with CIM, IFC and IEC 61850 SCL mappings.
  • Tolerant reading of unambiguous near-miss values (poles: 2, cores: "3G2.5", range_A: [15, 45]...), each reported by the rule core.normalized; installation.premises scopes dwelling-only rules.
  • LLM tools (guide): reference card generated from the model (uniwire card), text outline with stable ids (uniwire describe), id-based edits (uniwire patch), flat node table, links that open a document in the web editor (uniwire link, viewer_url in the MCP tool results).
  • MCP server uniwire-mcp (extra uniwire[mcp]): stdio and HTTP transports, tools to validate, check, describe, patch, render and export documents, bundled examples; a public mode with bounded inputs, worker processes and timeouts, short editor links (--store) and a usage log without caller addresses, used by the hosted endpoint https://mcp.uniwire.sh/mcp; every tool has a title and read-only annotations; check results state their scope (automatic checks, not a conformity certificate). Setup for ChatGPT, Claude, Cursor and VS Code: uniwire in your assistant.
  • LLM evaluation tasks with a runner that makes no network calls (evals/llm).
  • Hardened parsing: bounded quantity and reference parsers, nesting limit, CSV formula neutralisation, XML-safe SVG, PDF and CSV output.
  • 52 example documents (examples): dwellings, commercial and industrial boards, MV/LV substations, standby sources, PV, EV charging, UPS, PLCs.
  • Optional IEC 81346-2 class table in the separate data package uniwire-data-iec81346 (CC BY-SA 4.0), pip install "uniwire[iec81346]".
  • Draft proposal UEP-0001 "Terminals, terminal strips and wires" for format 2.0.